Article details

Lid-3300ip ice sensor

Date: 2021-12-24 00:58
Views: 0
Abstract: lid-3300ip ice detector is specially designed for wind turbine, weather station and airport application, and they are located in the area with icing risk. The lid-3300ip ice detector can detect icing in the time interval between heating and cooling of special sensor wires. The sensing signal of ice sensor is controlled by digital. When the preset limit is reached, the system will send out ice warning alarm. Lid-3300ip is easy to connect to wind turbine control system using relay output, current data, serial RS-232 or TCP / IP interface. The built-in web user interface can be used to monitor ice conditions, alarms and parameters, and adjust parameters.

Introduction of lid-3300ip ice sensor of Finland labkotec company



1. Introduction to labkotec oy, Finland

Finland Labkotec Oy The company operates in the field of ice detection and identification technology and related network-based measurement data control and monitoring system. Labkotec has over 57 years of product design and manufacturing experience in the field of environmental protection. Our products based on our own design and manufacture have gained a superior position in the market.

2. Lid-3300ip 2 ice sensor

LID-3300IP Ice detectors are designed specifically for wind turbine, weather stations and airport applications and are located in areas where there is a risk of icing. The lid-3300ip ice detector can detect icing in the time interval between heating and cooling of special sensor wires. The sensing signal of ice sensor is controlled by digital. When the preset limit is reached, the system will send out ice warning alarm.

Lid-3300ip is easy to connect to wind turbine control system using relay output, current data, serial RS-232 or TCP / IP interface. The built-in web user interface can be used to monitor ice conditions, alarms and parameters, and adjust parameters.

Lid-3300ip 2 brief technical parameters: output: two sets of switch output, one set of ice alarm; Whether the other group has internal fault alarm; Two groups of analog quantity are 4mA to 20mA ", one group of analog output ice signal amplitude level (0-100, normal no icing is 100, when alarm is about 16mA, ice amplitude value is about 60, 0 represents unlimited icing * large); the other group analog output environment temperature / sensor temperature.

Output port: two groups of switching value and two groups of analog quantity; Common 1 group of input and output interfaces; RS232 interface, optical fiber interface, RJ45 network cable interface.

Power supply: 220 VAC, 50 Hz

Power consumption: 7W; 350 W (self heating and ice melting)

3. Lid-3300ip 2 ice sensor Typical applications: wind turbines, airports and meteorology

LID-3300IP More than 10000 wind turbines have been used; Generally installed in the airport flat weather mast, such as Helsinki capital airport, installed 6 sets Ice Detector Once the ice alarm is sent out, it will be sent to the flight tower to judge whether the conditions for taking off are met, so as to protect the safety and stability of the people and the aircraft.