C9110d and 9110f vibration calibrators

Date: 2021-12-24 00:58
Views: 17
Abstract: model 9110f accelerometer sensor test device and calibration system NSN national stock number: 6635-01-692-7511 Model 9110f with accessories The model 9110f portable vibration calibrator kit for aeronautical applications, similar to the model c9110d charge amplifier input portable vibration calibrator, is a sensor test device with a set of enhanced accessories designed for various vibration sensors for rotor track and balancing, dynamic propeller balancing and turbine engine balancing in aviation applications. Model 9110f is a modern version of dynamic instruments di  ̄ 811a vibration calibrator with decades of history, which greatly improves the accuracy. It displays pass / fail notification after each test point, provides linear calibration, provides self-test function, does not need to return to OEM, can be controlled by SCPI command, and is equipped with accessories required for turn key operation. Like the di-811a, the 9110f performs automatic payload calculations. The user is never prompted to enter the quality of the sensor under test.

Model c9110d and 9110f vibration calibrators

 




1、 Mdel c9110d vibration calibrator of PCB company


C9110D Portable calibrator of charge type acceleration sensor The function of charge amplifier input is added to support the calibration of single ended and differential output charge type acceleration sensors. PVC with built-in charge amplifier input and BNC Jack input interface of charge mode accelerometer replace external source input interface on 9110d. When using charge input, set the knob charge on / off to on, otherwise set it to off.


  • In the test settings menu, set the sensor type to charge
  • According to the amplitude, the display will display PC / g, PC / M / S2, etc
  • The data is stored in the memory in PC unit
  • The calibration report generation workbook provided creates calibration certificates in PC units
  • During the calibration process, the charge amplifier scale factor is automatically saved to the firmware. Calibration values are used, not nominal values
  • Through the options menu, the user can adjust the charge amplifier scale factor, which is not recommended
  • The charge amplifier scale factor is provided on the calibration certificate of c9110d. When the c9110d returns to TMS for calibration, the internal charge amplifier is recalibrated. No other manufacturer has previously recalibrated the internal charge amplifier when PVC is returned to the factory
  • Even if the battery is powered off, the charge amplifier scale factor in the firmware will not be lost

The model c9110d vibration calibrator creates calibration reports in accordance with ISO 17025 for the following types of vibration sensors:

  • Built in amplifier circuit piezoelectric (ICP ®) sensor

  • Differential output piezoelectric charge sensor

  • Piezoelectric charge sensor with single output

  • Moving coil (self generating voltage output) sensor

  • Piezoresistive sensor (external bridge signal adapter required)

  • Displacement (eddy current) sensor

  • Capacitive sensor (external signal adapter required)

  • Modulated current vibration sensor (need external signal adjustor)

Model c9110d vibration calibrator Product features and advantages:

  • Portable, lightweight design, long battery life. C9110d can be carried to the working site of steam turbine for loop inspection, fault diagnosis and calibration of high temperature differential acceleration sensor and its monitoring system

  • Step sine programming can be carried out to provide pass / fail prompt for each test point

  • The sensitivity display can be easily switched between PC / g and MV / g, which is convenient to determine the error source in the measurement chain of charge type acceleration sensor

  • It is directly connected with the built-in quartz crystal reference acceleration sensor, so that users can confirm the accuracy of the vibration exciter without returning to the factory

Each c9110d portable vibration calibrator with charge amplifier input is provided with the following accessories:

  • Two mounting plates are specially designed for 3-hole and 4-hole bolt mounting methods commonly used in high-temperature differential piezoelectric charge type acceleration sensors and moving coil sensors

  • USB flash drive with calibration report generation workbooks. This workbook is a macro enabled Microsoft Excel ® Template, no other software is required. Any installation of Microsoft Excel ® The same workbook can be used to program the c9110d on all computers

Model c9110d vibration calibrator Main indicators:

  • The accuracy is ± 3% in the range of 10 Hz to 10 kHz and ± 5% in the range of 5 Hz to 10 Hz

  • Low frequency response up to 5 Hz

  • Provides on-site drift test and accuracy check procedures directly connected to the built-in quartz crystal reference accelerometer

  • Each programmed test point can provide a pass / fail prompt

  • Calibration reports can be created for both frequency response and linearity

  • The payload is calculated automatically, and the * * result can be obtained without inputting mass

  • Battery life up to 18 hours
    Problems caused by power failure during battery replacement can be remedied through factory calibration service

2、 PCB mdel 9110f vibration calibrator | calibrator (NSN National stock number: 6635-01-692-7511


The model 9110f, like the model c9110d, is a PVC package for aerospace applications. It also includes the following accessories:

  • Differential DC voltage source is used in Honeywell 7310 & 8866-1 speedometer. Including matching connector, model 9100-ps06
  • DC voltage source for three wire 9VDC Wilcoxon 991d vibration and similar sensors. Including matching connector, model 9100-ps09
  • DC voltage source for modulating current and loop powered 24 VDC sensor, model 9100-ps02
  • Single axis ICP ®& Cable for charge type acceleration sensor, 10-32 to BNC, model 003c03
  • Three axis ICP ® Acceleration sensor cable, 4-hole Bendix to 3bnc, model 9100-cbl01
  • Supporting cable for moving coil speed sensor, model 045et005ac
  • Adhesive mounting object, model 9155-mnt07
  • Right angle triaxial mounting block and support plate, model 9100-mnt03
  • Usb-usb communication cable, model 9100-usb00
  • Precision calibration acceleration sensor with ISO17025 certification frequency sweep calibration certificate, model 353b03

Similar to the model c9110d charge amplifier input portable vibration calibrator, the model 9110f aviation application portable vibration calibrator kit is a sensor test device with an enhanced set of accessories designed for various vibration sensors for rotor track and balancing in aviation applications, dynamic propeller balancing and turbine engine balancing. Model 9110f is a dynamic model with decades of history The modern version of di  ̄ 811a vibration calibrator of instruments company greatly improves the accuracy. It displays pass / fail notification after each test point, provides linear calibration, and provides self-test function. It can be controlled by SCPI command without returning to OEM, and is equipped with accessories required for turn key operation. Like the di-811a, model 9110f performs automatic payload calculations. The user is never prompted to enter the quality of the sensor under test.
The model 9110f vibration calibrator is also a NIST traceable vibration source for verification ACES Systems Balance kits and vibration analyzers manufactured by MTI instruments and other equipment. The 9110f is equipped with a vibration analyzer calibration manual, which allows technicians to be probalancer from aces systems 2020、 Viper II Cobra II And atabs balance analyzer and MTI pbs-4100 + linear and frequency response to create NIST traceable calibration certificate. For pbs-4100 +, model 9110f and balance analyzer have BNC input, which makes cable connection simple. Users can troubleshoot the model 41Ca of MTI instruments and the model 510 charge amplifier of aces systems.
The model 9110f is equipped with a calibration certificate to confirm its accuracy. Model 9110f was calibrated by the American Society for Laboratory Accreditation (A2LA) in accordance with ISO 17025 standard certification. The transmission standard used is in ISO The uncertainty budget of 16063-11 laser primary calibration system is lower than that of all systems in the United States. You can check the certification scope of modal shop company here.

The user groups of model 9110f vibration calibrator and calibrator include:

  • Military applications
  • Commercial aviation, especially customers using aces system to balance components
  • Customers using Wilcoxon 991d & 993a acceleration sensors (ACES systems customers)
  • Customers with high temperature moving coil vibration sensor
  • Customers of organic accelerometer

About aces systems:


ACES Systems Its parent company is technology for Energy Corporation (tec-usa), which provides simple solutions to complex problems in nuclear power, material testing, power, aviation and other important industries. Aces sywtems was acquired by technology for Energy Corporation in 1990. It provides vibration analysis, balance, engine performance analysis, intake guide vane adjustment and other systems for aviation customers worldwide, and has become a benchmark in the industry. Aces systems products include: ProBalancer two thousand and twenty Viper II Cobra II And atabs vibration and Balance analyzer